lfaSpid Rotator RAK1 http://Alfaspid.com http://www.hy-gain.com Page 18
Page 18 of 21
A
lfaSpid Rotator RAK1
http://Alfaspid.com http://www.hy-gain.com
Copyright
A
lfaRadio Ltd. 2002-2008
Relays chosen should be suitable for the proper coil voltage as well as appropriate
current carrying capability. A relay capable of 5 to 10 amps DC is adequate. The
diode in series with Relay K1 is any general purpose 1 amp style such as the 1N400x
series. If the motor rotates incorrectly, simply reverse the leads to the motor or from
the External DC Supply.
The controller also has the capability to, with a small modification, allow you to
input your external DC voltage into the unit and use the internal relays to control the
rotator as usual.
This information is presented as a guide to help the user realize a solution to
the long cable run situation.
Prepared for
A
lfa Radio Ltd. by VE6JY Don Moman Dec 6/2001